title: "Reverse Osmosis Plants | Civic Water Engineering"
url: https://civicwater.co.za/services/water-treatment/reverse-osmosis
description: "Reverse osmosis plants for saline and high-TDS water: pre-treatment, recovery, brine management and membrane care, engineered by Civic Water Engineering."
lang: en-ZA
---

Skip to content

Water Treatment

# Reverse Osmosis Plants

Reverse osmosis removes dissolved salts and other substances that filters cannot. CWE designs RO plants around the source water, the recovery a site can afford and a responsible plan for brine.

START A PROJECT
010 730 0051: +27107300051

- For saline and high-TDS water
- Brine management planned
- Monitored membrane performance

Image: Reverse osmosis skid with membrane housings, control panel and stainless steel product water tank (https://civicwater.co.za/__l5e/assets-v1/2b8cd15d-608a-4d4f-bfcb-5e2c46f87845/cwe-reverse-osmosis-skid-membranes-stainless-tank.webp)

When RO is needed

## When filtration is not enough

RO is the right tool when water carries too much dissolved material: salinity, high total dissolved solids, nitrates or fluoride. These pass straight through conventional filters.

Because RO membranes are sensitive, pre-treatment is designed first to protect them from scaling, fouling and chlorine damage.

Enquire about water treatment

Image: Softener vessel, brine tank and reverse osmosis unit inside a plant room (https://civicwater.co.za/__l5e/assets-v1/c1921edf-bc61-4b7c-8026-05859bdd3add/cwe-softener-reverse-osmosis-plant-room.webp)

Design factors

## Pre-treatment, water recovery and brine disposal

Every RO plant balances water quality, recovery and running cost.

Enquire about water treatment

Key design factors

| Factor | Why it matters |
| --- | --- |
| Pre-treatment | Protects membranes from solids, iron, hardness and chlorine |
| Recovery | Share of feed water becoming product; higher recovery means less brine |
| Brine management | Concentrate must be disposed of or reused responsibly |
| Membrane care | Cleaning, monitoring and replacement keep output stable |

Compliance

## Drinking water and process water requirements

Product water is designed to meet the end-use requirement, whether drinking or process water.

Discuss your water requirements

Included in design

- SANS 241 drinking water quality where potable
- Remineralisation where required
- Brine disposal plan
- Online conductivity monitoring
- Operator training and O&M manuals

## Reverse osmosis questions

Common questions about RO plants.

Talk to a specialist

010 730 0051 (+27107300051)START A PROJECT

### How much water does RO waste?

RO produces a concentrate stream. Recovery depends on the feed water; well-designed pre-treatment allows higher recovery and less brine.

### What do you do with the brine?

Options include evaporation, approved discharge, blending or reuse, depending on volume, site and regulation. The plan is part of the design.

### How often do membranes need replacing?

Membrane life depends on feed water and care. Good pre-treatment, cleaning and monitoring extend it considerably.

### Is RO water safe to drink?

Yes, when the plant includes disinfection and, where needed, remineralisation, and is designed to SANS 241.

## Related services

### Water Treatment Plants & Systems

The full range of water treatment systems.

Read more
https://civicwater.co.za/services/water-treatment

### Containerised Water Treatment Plants

RO delivered in a relocatable container.

Read more
https://civicwater.co.za/services/water-treatment/containerised-plants

### Borehole Water Treatment

Treatment for common borehole water issues.

Read more
https://civicwater.co.za/services/water-treatment/borehole-water-treatment

### Water System Monitoring & Maintenance

Remote monitoring of membrane performance.

Read more
https://civicwater.co.za/services/monitoring-maintenance

## Plan your RO plant

Share your water test results, daily volume and end use. A CWE specialist will recommend a next step.

010 730 0051 (+27107300051)enquiries@civicwater.co.za

HEAD OFFICE

2 Bream Rd, Wadeville, Germiston, 1428: https://www.google.com/maps/search/?api=1&query=2%20Bream%20Rd%2C%20Wadeville%2C%20Germiston%2C%201428

CAPE TOWN

Unit 9, 12 Square Street, Watershed Park, Stikland Industrial, 7530: https://www.google.com/maps/search/?api=1&query=Unit%209%2C%2012%20Square%20Street%2C%20Watershed%20Park%2C%20Stikland%20Industrial%2C%207530

## Structured data

```json
{
  "@context": "https://schema.org",
  "@type": "BreadcrumbList",
  "itemListElement": [
    {
      "@type": "ListItem",
      "position": 1,
      "name": "Home",
      "item": "https://civicwater.co.za"
    },
    {
      "@type": "ListItem",
      "position": 2,
      "name": "Services",
      "item": "https://civicwater.co.za/services"
    },
    {
      "@type": "ListItem",
      "position": 3,
      "name": "Water Treatment",
      "item": "https://civicwater.co.za/services/water-treatment"
    },
    {
      "@type": "ListItem",
      "position": 4,
      "name": "Reverse Osmosis",
      "item": "https://civicwater.co.za/services/water-treatment/reverse-osmosis"
    }
  ]
}
```